Roubleshooting, Pecifications – Minka Group F702-VB User Manual
Page 15

13. T
ROUBLESHOOTING
Problem
Solution
Fan will not start 1. Check fuses or circuit breakers.
2. Check line wire connections to fan.
CAUTION: Make sure main power is off.
3. Check to make sure the dip switches from the
transmitter and receiver are set to the same frequency.
Fan sounds noisy. 1. Allow a 24-hour "break-in" period. Most noises
associated with a new fan will go away during this time.
2. Make sure all motor housing screws are snug.
3. Make sure that the screws that attach the fan bade
bracket to the motor hub are tight.
4. Make sure your outlet box is secured and rubber pads
were used between the hanger bracket and outlet box.
Fan Wobble 1. Check that all blade and blade holder screws are
secured.
2. Use the enclosed blade balancing kit if blade
wobble is excessive. (See instructions included with
the balancing kit.)
NOTE: All blade sets are grouped by weight. Because
natural wood blades vary in density, the fan may wobble
even though blades are weight matched.
14. S
PECIFICATIONS
These are typical readings. Your actual fan may vary. They do not include Amps
and Wattage used by the light kit.
RPM CFM N.W.
G.W.
52"
120
120
120
Fan Size Speed Volts Amps Watts
Low
Medium
High
15
32
67
74
114
172
1035
4000
5600
11.96
kgs
13.44
kgs
2.66'