Installation – Magikitch'n FM User Manual
Page 7

Installation
GAS CONNECTION 
An adequate gas supply is required for proper broiler 
performance. With all burners on “HIGH”, the manifold 
pressure should not show any appreciable drop. 
Fluctuations of more than 25% will create pilot problems 
and affect burner operation. 
WARNING!! 
This unit must be connected ONLY to the type 
of gas specified on the rating plate. 
1. Remove the hairpin clips securing the burners. This
will allow for removal of the burners for inspection, 
cleaning and servicing. 
2. Attach the regulator supplied with the unit. The
regulator must be installed at the entry end of the gas 
manifold. 
NOTE: Be sure the regulator is installed so that the
gas flows in the same direction as the 
arrow on the bottom of the regulator. Use 
the supplied regulator only. Use of any 
other regulator will invalidate the 
warranty. 
3. Adjust the regulator to the burner pressure listed on
the rating plate. Refer to the table on the following 
page for proper pressure settings. 
NOTE: A pressure regulator is not required for all
countries.
4. Use pipe joint compound suitable for use with LP
gas on all threaded connections.
5. Turn off all burner valves. 
6. Turn on the gas supply. Check all connections for 
gas leaks using soap and water. Never use an open 
flame to check for gas leaks! 
GAS CONVERSION 
All units are shipped with the appropriate orifices and 
components required for the gas requested. If the unit 
does not perform well or has unsatisfactory flame 
characteristics (too high, yellow tips, lifting), check that 
the supply pressure and orifice size are appropriate for 
the gas used before making any adjustments. 
Use the following directions to convert the unit to a 
different type of gas if necessary. Each conversion kit 
contains all the orifice sizes and markings required for 
converting any size unit to any gas type in all countries. 
Note that in Belgium units may not be converted. For 
some conversions it may also be necessary to replace the 
regulator or restrictor orifice. 
NOTE: Refer to the table on the following page to 
determine gas requirements, pressure settings 
and orifice sizes. 
1. Shut off the gas supply to the unit. 
2. Disconnect the unit from the gas supply. 
3. Remove the top grids, radiants, runner tubes and 
burners.
4. Remove the brass runner tube orifice. Replace with
the new orifice.
5. Remove all burner orifices. Replace with the new
orifices.
6. Adjust the air shutters on all the burners to the
correct opening. Mark the air shutter at the correct 
setting. Re-install the burners. 
7. Re-install the runner tubes, radiants, and top grids. 
8. Adjust the regulator to the correct gas pressure. If a 
restrictor orifice is required in place of the regulator 
to meet your countries specific codes, remove the 
old restrictor orifice and replace it with a new one 
correctly sized to provide the burner pressure 
specified for the gas type being used. 
9. Adhere the appropriate conversion sticker to the
front of the unit, near the rating plate.