ADJUSTMENT SPLASH GUARDSWASHING/SCRUBBING
BASE (brooms)
Figure 60
Periodically proceed with the height adjustment of the side
splashguards of the base. This operation has to be carried out with the
base down.
1.

Loosen the fixing lock nut of the support bars (1).

2.

Regulate the splashguards with the screw (2).

3.

Block the lock nut (1). Keep in mind that the rubber must skim
the floor and be parallel to it.







CLEANING OF THE SUCTION HOSE
Figure 61
Whenever suction seems to be unsatisfactory, check that the suction
hose is not obstructed. Eventually, clean it with a water jet introduced
from the side where it is being connected to the tank. Proceed as
follows:
1.

Loosen the clamp, which tightens the hose.










Figure 622.
2.

Clean with a water jet introduced from the side where it is
connected to the tank.

3.

Reassemble everything proceeding inversely with above
operations.

ATTENTION: this operation must be made by using gloves to protect
from the possible contact with dangerous materials and solutions.