beautypg.com

Cleaning of the recovery tank, Cleaning of the squeegee, Replacement of the squeegee rubber – NaceCare Solutions ST995 User Manual

Page 17

background image





CLEANING OF THE RECOVERY TANK
Figure 46
1.

Empty the tank through the flexible hose, unscrewing of
some turns the knob and then taking off the plug

ATTENTION: this operation must be made by using gloves to
protect from the contact with dangerous solutions.










Figure 47
2.

Open the side plug by unscrewing the knob and rotating the
closing blade

3.

Rinse the tank and clean the exhaust plug

4.

Check the perfect position of the side plug gasket

5.

Retighten the side plug and the plug onto the exhaust pipe.












CLEANING OF THE SQUEEGEE
Clean the squeegee with a water jet. Check the rubber wear and if
necessary, turn them upside-down or change them. The careful
cleaning of the complete suction group assures higher life of the
suction motor.














REPLACEMENT OF THE SQUEEGEE RUBBER
Figure 48
If the squeegee rubber is worn and does not dry well, it is possible
to change the drying edge proceeding as follows:
1.

Push and rotate the fixing plates

2.

Slip off the rubber blade and the rubber itself

3.

Turn the rubber upside-down and if necessary, replace it

4.

Adjust the squeegee height as indicated in “ADJUSTMENT
HEIGHT SQUEEGEESUPPORT” under
“MACHINEPREPARATION”

- 16 -

5.

Reassemble everything repeating inversely above operations.





This manual is related to the following products: