Figure 42
Having finished the job and before any type of maintenance is
done:
1.

Close the cock (1).

2.

Push the brushes base switch (2) into the UP position, till
reaching the maximum UP position.











Figure 43
3.

Position the switch of squeegee up/down (1) into central
position, so that the suction motor keeps on working to empty
the suction hose for about 20 seconds, then position it into
the UP/OFF position.

4.

Bring the machine to the place provided for the water
outlet/drainage.

5.

Turn the key of the general switch (2) 1/4 round counter-
clockwise.








Figure 44
6.

Take off the exhaust pipe from its hook, unscrew the exhaust
plug and empty the recovery tank. To simplify draining
operation, it is recommended to hold the hose bent with one
hand and with the other unscrew the knob and take off the
plug. Slowly straighten the hose and the liquid will start
draining at the desired speed. This operation has to be carried
out using gloves to protect from contact with dangerous
solutions.

ATTENTION: This operation must be made by using gloves to
protect from the contact with dangerous solutions.
7.

The squeegee has to be lifted when the machine is not
operating. In this way damage to the squeegee rubbers is
avoided.

8.

Take off the brushes and clean them with a water jet (for the
brushes disassembly please read further on under
“DISASSEMBLY OF THE BRUSHES”).




Figure 45
Remove the hopper unit (if washing/sweeping unit is being used)
to empty debris, and then clean out carefully.
ATTENTION: This operation must be made using gloves to
protect from the contact with dangerous solutions.