NaceCare Solutions RM1800F User Manual
Page 5
5
6. Connect the plug of the machine to a grounded electrical socket. If the electrical socket
does not have a built in GFI (Ground Fault Interrupter) please use the GFI provided.
Carefully read the instructions in the safety instructions paragraph.
7. Prepare the area to be cleaned by picking up the large debris and flushing any toilets or
urinals that require it.
8. Remember to wear gloves, goggles, and any other necessary safety equipment required
by law in your area.
Working process
A. Applying the foam
B. Manual brushing (optional)
C. Rinsing
D. Squeegee mirrors and flat surfaces
E. Vacuuming
F. Blow dry fixtures (optional)
STEP A – APPLYING THE FOAM
1.
Set up the machine just outside the door of the area to be cleaned.
2.
Switch the foam pump and the air
compressor on. The Foam pump is the
far left switch on the upper control
panel.
3.
Open the water valve located on the
ball valve where the hose connects to
the machine
4.
Spray until you get a constant stream of water coming out of the spray gun