Operating Procedure:
SQ: Squelch Setting
1. Press the rotary controller to activate and move the cursor to the SQ parameter. When the SQ
cursor starts to flash, the squelch level is ready to be set.
2. Rotate the rotary controller clockwise to increase the SQ level; counterclockwise to decrease the
level.
3. Press the rotary controller once to confirm and save the selected SQ level or wait 5 seconds (without
touching anything) and the parameter will automatically be saved.
8
NOTE:
The higher the level indicators, the lower the sensitivity - which shortens the transmission range. The
lower the level indicators, the higher the sensitivity which increases the transmission range. However, when the
SQ is set at full level (5 bars), the "AutoScan" function will be disabled and users can freely select any group or
channel manually.
GRP
CH
BAND
ANT
MHz ACT
RF
AF
BA
EQ
SQ
ADD
SQ cursor starts flashing
Rotate clockwise to increase the setting by one bar
Rotate counterclockwise to decrease by one bar
8
10
11
GRP cursor starts flashing
Turn clockwise to increase by one group
Turn counterclockwise to decrease by one group
Operating Procedure:
GRP: Group Setting
1. Press the rotary controller to activate and move the cursor to the GRP parameter. When the GRP
cursor starts to flash, the Group is ready to be set.
2. Rotate the rotary controller clockwise to increase the Group number; counterclockwise to decrease
the Group number.
3. Press the rotary controller once to confirm and save the selected Group number (or wait for
autosave).
8
GRP
CH
BAND
ANT
MHz ACT
RF
AF
SQ
BA
EQ
ADD
Refer to the supplied channel plan for your band to select a specific frequency.