OPTION 2

For exterior applications (steel

stud walls and standing seam
metal roofs).
1. Measure and cut

WEATHERMATE™ Straight
Flashing (4" or 6" width) to cover full
length of insulation boards. (Flashing
is applied on the exterior of steel
stud walls and exterior/top edge of
standing seam metal roofs.)

2. Peel back part of release liner

and center flashing over dry,
clean edge joint.

3. Remove release liner while

pressing flashing firmly along
the joint. (Figure 2)

OPTION 3

Requires shiplap edge boards

1. Apply GREAT STUFF PRO™

Gaps & Cracks Insulating Foam
Sealant* or a compatible
construction grade sealant to
shiplap edge, following
manufacturer instructions.

2. Fit next THERMAX™ board

firmly into the sealant-lined
shiplap edge and fasten.
(Figure 3)

3. Center THERMAX™ tape over

dry, clean edge joint and apply
tape.

4. Use a squeegee or stiff bristle

brush to press the tape firmly to
the joint. Cut tape with a knife.
Do not tear tape.

OPTION 4

Requires square edge boards

1. Fasten Clip Strip to wall or

ceiling through holes provided
at 12" o.c. with pneumatic
nailer or equivalent.

2. Adjust Clip Strip to insulation

board to allow for correct width.
Align each PVC section 1/8"
from the insulation board mark
and attach.

3. Apply a construction-grade

sealant to the single long flange
of the Clip Strip, following
sealant manufacturer
instructions.

4. Slide THERMAX™ Insulation

boards into place as shown.
(Figure 4)

Note: High-humidity metal buildings

may require two insulation layers for
optimum moisture control. Visit
www.DowMetalBuilding.com for installation
recommendations for high-humidity
applications (Form No. 179-04338).

OPTION 5

For direct adhesion to concrete or

masonry walls

1. Fasten base section of

Interlocking System to concrete
or masonry wall through holes
provided at 12" o.c. with
pneumatic nailer or equivalent.

2. Adjust base strip to insulation

board to allow for correct width.
Align each PVC section 1/8"
from the insulation board mark
and attach.

3. Apply beads of construction

grade adhesive to the concrete
centered 16" o.c. between the
PVC strips.

4. Press board firmly into position

between the PVC base strips
and allow curing time, following
adhesive manufacturer
recommendation.

5. Apply a continuous bead of

sealant along the face of the
boards next to the joint.

6. Guide the top PVC section

along insulation board edge
until it snaps into the
Interlocking System base.
(Figure 5)

P R O D U C T / I N S T A L L A T I O N I N F O R M A T I O N

.

C O M M E R C I A L

.

P R O T E C T I O N M A N A G E M E N T

Figure 2

Figure 3

Figure 4

®™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow
*Consult label and MSDS carefully before use.

Figure 5

Shiplap Edge Treatment

THERMAX™ Insulation with WEATHERMATE™

Flashing Applied

PVC attached to tilt-up wall

View from above – looking down wall

View from above – looking down wall