6.47 LAU_CONFIG_GETANALOGTOBRT
(0x011F)
Analog to Brightness Routing Mode
Some Beijer Electronics Nautic Monitor models are equipped with an expansion
port, where an analog potentiometer or a variable voltage can be connected, to con-
trol the backlight level of the monitor. This command returns the configuration of
the analog input port usage. If the analog port control is enabled, the backlight level
cannot be changed using the front panel keys, digital input or SCOM commands.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Check whether the monitor at address 0.7 (group 0, address 7) is configured to use
the analog input for setting the backlight level:
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitor does not use analog input for backlight level control:
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x01
0x1F
ICHKD
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0x00: Routing from analog input to backlight level control disabled
0x01: Routing from analog input to backlight level control enabled
Type:
Byte
Length:
1
Description: Configuration of the analog input port usage
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x01
0x1F
0xDF
0
1
2
3
4
5
6
7
8
0x06
0x07
0x4C
0x41
0x55
0x01
0x0F
0x00
0xFF