44 lau_config_getremotecontrol (0x011c), Remote control configuration, Lau_config_getremotecontrol (0x011c) – Beijer Electronics SCOM Protocol EN User Manual
Page 80
Command Reference
80
Beijer Electronics, MAEN975
6.44 LAU_CONFIG_GETREMOTECONTROL
(0x011C)
Remote Control Configuration
This command returns the configuration value that indicates whether the monitor is
configured to act as a remote controller. Beijer Electronics Nautic Monitors can be
used as passive devices, but can also be set up as remote controller devices to alter the
backlight level of any other monitor within the network.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Check if the monitor at address 0.7 (group 0, address 7) is configured to control oth-
er devices remotely within a network:
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the monitor is capable to control other devices remotely within a network:
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x01
0x1C
ICHKD
0
1
2
3
4
5
6
7
8
0x06
ADR
0x4C
0x41
0x55
0x01
ICHKH
Ret
ICHKD
Ret
Value:
0x00: Remote control capability is disabled
0x01: Remote control capability is enabled
Type:
Byte
Length:
1
Description: Indicates, whether the monitor is used also as remote controller
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x01
0x1C
0xE2
0
1
2
3
4
5
6
7
8
0x06
0x07
0x4C
0x41
0x55
0x01
0x0F
0x01
0xFE