Beijer Electronics SCOM Protocol EN User Manual
Page 23
![background image](/manuals/459993/23/background.png)
Command Reference
Beijer Electronics, MAEN975
23
Maximum Lr for this Command
9
Example 1
Disable the local control of monitor at address 0.7 (group 0, address 7):
Monitor at address 0.7 (group 0, address 7) has acknowledged, that the local control
is disabled:
Example 2
Send an invalid “POT” command to the monitor at address 0.7 (group 0, address 7).
The command uses an invalid value 0x90 for “Local control”:
Monitor at address 0.7 (group 0, address 7) has not accepted the command. Instead,
it sent a negative acknowledge with the current local control mode 255 (0xFF):
0
1
2
3
4
5
6
7
8
0x07
0x07
0x50
0x4F
0x54
0x01
0xFD
0x00
0xFF
0
1
2
3
4
5
6
7
8
0x06
0x07
0x50
0x4F
0x54
0x01
0xFE
0x00
0xFF
0
1
2
3
4
5
6
7
8
0x07
0x07
0x50
0x4F
0x54
0x01
0xFD
0x90
0x6F
0
1
2
3
4
5
6
7
8
0x15
0x07
0x50
0x4F
0x54
0x01
0xEF
0xFF
0x00