33 lau_config_getcombaud (0x0111), Scom serial interface baudrate, Lau_config_getcombaud (0x0111) – Beijer Electronics SCOM Protocol EN User Manual
Page 69
Command Reference
Beijer Electronics, MAEN975
69
6.33 LAU_CONFIG_GETCOMBAUD (0x0111)
SCOM Serial Interface Baudrate
Returns the configured baudrate for the SCOM communication over serial interface.
While the original SCOM specification defines only one baudrate at 9600 bits/sec-
ond, Beijer Electronics Nautic Monitors can be configured to use another baudrate
than the given default.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
12
Example
Get the serial interface baudrate of the monitor at address 0.7 (group 0, address 7):
According to the data returned by the monitor at address 0.7 (group 0, address 7),
the serial interface is configured at 9600 bits/s (0x2580):
0
1
2
3
4
5
6
7...8
9
0x07
ADR
0x4C
0x41
0x55
0x02
ICHKH 0x01
0x11
ICHKD
0
1
2
3
4
5
6
7...10
11
0x06
ADR
0x4C
0x41
0x55
0x04
ICHKH
Ret
ICHKD
Ret
Value:
300...115200
Type:
Unsigned long
Length:
4
Description: SCOM serial interface baudrate, where the first byte is LSB
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x01
0x11
0xED
0
1
2
3
4
5
6
7...10
8
0x06
0x07
0x4C
0x41 0x55 0x04 0x0C 0x80
0x25
0x00
0x00
0x5A