7
1. Complete the daily cleaning
instructions (pages 5-6).
CAuTIoN: Make sure
the oven is off before
proceeding.
2. remove the air filter.
3. Clean the cooling fans and
finger guards.
NoTE: A bristle or paint
brush and vacuum are
recommended for collecting
the debris.
4. Clean the louvers on both
side panels.
NoTE: A bristle or paint
brush and vacuum are
recommended for collecting
the debris.
5. using a Phillips screwdriver,
remove the screws from the
rear vent catalyst housing.
Support the cover with your
hand.
6. The catalytic converter is accordion
style and will pop out when the cover
is removed. remove the cover slowly
to keep the catalytic converter in place.
CAuTIoN: Do NoT attempt to
clean the catalytic converter or spray
chemicals in this area.
7. Clean the housing:
- Hold the catalytic converter in place
with one hand.
- using a clean towel, wipe out any
debris that has accumulated beneath
the catalytic converter.
- Clean the outer cover and make
sure the vent holes are not blocked.
8. reattach the outer cover, making sure
the vent holes are at the bottom.
CAuTIoN: Installing the outer
cover upside down could result in
excessive grease buildup and/or hot
steam present when the oven door is
opened.
10.reinstall the air filter. The oven is
ready to turn on.
9. Wipe down the back panel with a
clean, damp towel.
Quarterly Maintenance
To ensure optimal oven performance, complete the
following cleaning steps once per quarter or more
frequently as required.
Supplies and Equipment
required: Phillips screwdriver, clean towels, rubber gloves
for handling catalytic converter.
recommended: dust mask, vacuum, bristle or paint brush