beautypg.com

Pulsafeeder PULSAlarm User Manual

Page 15

background image

15

1. Connect a vacuum pump to the top fitting of the fluid fill device. Open BOTH valves

on the device.

2. Place the lower fill tube into the container of the barrier fluid

3. Using the vacuum function, use the hand pump to draw several ounces of fluid up into

the fill device.

4. Close both valves on the fill device

5. Remove the hose and fitting from the container, and connect the fluid fill device to the

inlet fitting on the pump head (the fitting with the needle valve).

6. Open the fill valve (needle valve) on the pump, and then open the two plastic valves on

the fluid fill device.

7. Switch the hand pump to the pressure function, and apply approximately 10-20 psi of

pressure to the fluid in the chamber. Once pressure is achieved, close the TOP valve
and disconnect the hand pump. There is now pressure pushing the barrier fluid into the
leak detection system.

8. Move the hand pump to the outlet side of the system, switch it to the vacuum function,

and continue with the filling process as outlined in the main document.