TEMPERATURE CONTROL AND FAN MOTOR REPLACEMENT


Before making any change, technician should:

1. Disconnect power to the cabinet

2. Remove screws from venturi and pull down



To change fan motor

– disconnect fan motor leads – remove screws from fan guards and motor mounts.


To change a temperature control

– pull off the control knob and remove screws from the control – unplug the control

leads and replace with a new control

– put screws back in control and press on control knob.




FINAL CHECK LIST


A.

Check operating pressures.


B.

Check electrical requirements of unit to supply voltage.


C.

Set temperature control for desired temperature range. (factory recommended @ #6)


D.

Check sight glass for proper refrigerant charge (if provided)


E.

Check condensing unit for vibrating or rubbing tubing. Dampen and clamp as required.