beautypg.com

Nor-Lake AdvantEDGE Full Line Merchandiser Refrigerator User Manual

Page 8

background image

10/14 Rev A 159218

8

SERVICE INSTRUCTIONS

1. High head pressure and high back pressure:

A. Condenser coil clogged or restricted

B. Condenser fan motor defective.

C. Air discharge in rear of cabinet restricted.

2. Low back pressure and low head pressure:

A. Restriction in system.

B. Refrigerant undercharged.

C. Leak in system

3. Pressure normal

– cabinet warm:

A. Coil blocked with frost (see #4).

B. Refrigerant undercharged.

C. Control set too warm.

4. Cabinet not cycling

– coil blocked with frost:

A. Defective temperature controller.

B. Refrigerant overcharged.

C. Location too hot.

D. Condenser clogged.

E. Condenser fan motor defective.

5. Compressor starts and runs

– but cycles on overload:

A. Low voltage

B. Relay defective.

C. Overload defective.

D. High head pressure (see #1).