Nor-Lake AdvantEDGE Full Line Merchandiser Refrigerator User Manual
Page 6

10/14 Rev A 159218
6
ELECTRICAL
WARNING
Before servicing electrical components in the case or the doors or door frames make sure all
power to case is off. Always use a qualified technician.
Check voltage and amps drawn on (Page 12-15) to determine proper line and fuse or circuit breaker size. Check
power supply for low voltage. If voltage reads “120” with no load, and it drops below “100 or less” when the
compressor tries to start, it is an indication of too small supply wiring or too long to run.
It is recommended that a separate circuit be run for each cabinet to prevent another appliance blowing the fuse or
breaker, causing loss of product.
IMPORTANT
This cabinet is pre-wired internally for 120-
volt circuits. “Tapping” or feeding the 115-volt circuit from 230-volt supply
may result in overloaded circuit breakers or blown fuses and damage to electrical system, thereby voiding the
warranty.
The cabinet must be grounded.
TEMPERATURE CONTROLLER
The cabinet has a temperature control that is adjustable from # 0
(warmest setting) to # 9 (coldest setting). The controller is accessible
at the venturi inside the cabinet.
Temperature Control
Number indicator
Temperature Control