Sample, Lpl pl, 4 rating plate information – Napoleon Fireplaces GVF42 User Manual

Page 7

background image

7

W415-0379 / E / 04.24.12

2.4 RATING PLATE INFORMATION

CERTIFIED UNDER: ANSI Z21.11.2a-2008 VOLUME II, UNVENTED ROOM HEATER

W385-0248 / G

SERIAL NUMBER:

G/CVF42

WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET,
PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE
NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE
WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.

THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES
ADEQUATE COMBUSTION AND VENTILATION AIR. THIS UNIT IS NOT
APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION.

GVF42-N / CVF42-N

MODEL

GVF42-P / CVF42-P

**0-2000FT (0-610m)

ALTITUDE

0-2000FT (0-610m)**

30,000 BTU/h

INPUT

30,000 BTU/h

22,000 BTU/h

REDUCED INPUT

22,000 BTU/h

MANIFOLD PRESSURE: 3.5" WATER COLUMN

MANIFOLD PRESSURE: 10" WATER COLUMN

MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN

MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN

MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN

MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN

SIT CONTROL: #820637

SIT CONTROL: #820636

OPERATING PILOT OXYPROTECTOR: #8214

OPERATING PILOT OXYPROTECTOR: #8404

**

ABOVE 2,000FT, CONSULT LOCAL AUTHORITY HAVING JURISDICTION

NOT FOR USE WITH SOLID FUEL.

WARNING: FIREPLACE SCREENS MUST BE CLOSED WHILE IN OPERATION.

DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN

CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. DONOT USE BLOWER INSERT, HEAT EXCHANGER INSERT OR OTHER
ACCESSORIES NOT APPROVED FOR USE WITH THIS HEATER. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
TOP / SIDES / BACK / FLOOR 0”
RECESSED DEPTH

22“

MANTEL

2”*

MAXIMUM HORIZONTAL EXTENSION: 2". SEE INSTRUCTION MANUAL FOR GREATER
EXTENSIONS.

ELECTRICAL RATING: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT: GZ550-KT

9700539 (WSL)

4001657 (NGZ)

4001658

(NAC)

4001659

(WUSA)

This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.

INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.

For rating plate location, see “INSTALLATION OVERVIEW” section.

SAMPLE

IS

S

A

A

GA

GA

EQU

EQU

A

A

TE

TE

A

A

A

CO

CO

APP

APP

R

R

OVE

OV

D

D

FO

FO

R

R

B

I

I

N

N

S

S

T

T

ALL

AL

T

T

T

A

A

L TIO

TIO

A

A

N

N

.

MODEL

MODEL

ALTITUDE

ALTITUDE

INPUT

INPUT

REDUCED INPUT

REDUCED INPU

LLL

ER COLUMN

ER COLUMN

MANIFOLD

MANIF

ATER COLUMN

R COLUMN

MINIMU

MINIMU

WATER COLUMN

WATER COLUMN

MAXI

MAX

CONTROL:

CONTROL

#820637

#820637

SIT

S

XYPROTECTOR:

YPROTECTOR:

#8214

#8214

VE 2,000FT, CONSULT LOCAL

0FT, CONSULT LOC

N

N

OT FOR USE

OT FOR USE

BE CLOSE

E CLOSE

D WHILE

D WHILE

ED BY THE MANUFACTURER

THE MANUFACTURER

EATER. IMPROPER INSTALLA

PROPER INSTALLA

NFORMATION MANUAL PRO

NFORMATION MANUAL

TIBLE MATERIALS:

LE MATERIALS:

4001657 (NGZ)

4001657 (NGZ

4001659 (WUSA

4001659 (WUSA

L

L

PL

PL