K – ver. 1.3 – Sept. 2005
3
PRG
HOT AIR 30-250°C. All modes
and all optional extras are
described on following pages.
(Preheating up to 300°C is
optional extra on models C and K
but standard feature on model B)
REGENERATING / COMBI
STEAMING
Change between the modes by
pressing
REGENERATING
COMBI STEAMING 1
COMBI STEAMING 2
STEAM BOILING 30-120°C.
Used for manual humidity
pulsing in HOT AIR during
preparation.
EXHAUST is open when control
lamp is on.
Low FAN SPEED is active
when control lamp is on.
SETTING CORE TEMP. PROBE
(optional extra). Press once and set
with TURN SWITCH. Deactivate
by turning switch past the
permitted
temp. range of 30-99°C.
TEMPERATURE SETTING. Press
once and set temperature with
TURN SWITCH. Enter by pressing
symbol again.
If the oven does not incorporate COMBICLEAN, the manually operated cleaning system can be
activated by pressing the PRG key and turning the switch until CLEANING appears in the
display.
PROGRAMS (optional extra).
Press once and choose program
with TURN SWITCH. Editing and
deleting are described on follow-
ing pages.
ON/OFF
STEP shows current step when
PROGRAM mode is active.
Control lamp next to ALARM
lights up when alarm has been
chosen after a step (when PRG is
active).
Main switch
TIME SETTING. Press once and
set time with TURN SWITCH. 4
hours is maximum. Confirm by
pressing TIME.
Settings