30

Troubleshooting

Ice maker is not

producing ice

Temp Alarm Light
is flashing

All lights on
dispenser and
interior lights are
off and appliance
is still running

Door alarm set, no
alarm sounded

Temperatures in
display look too low

PROBLEM

POSSIBLE CAUSES

• Ice maker switch is not ON

• Household water supply is not

reaching water valve.

• Copper tubing has kinks.

• Water pressure is too low.

• Check freezer temperature.

• Inner fountain door is blocked or

frozen.

• Exceeded normal operating

temperatures.

• Control has been set to Sabbath

Mode.

• Alarm mode has been disabled.

• Temperature display has been set to

Celsius rather than Fahrenheit.

• Confirm ice maker switch is ON. See Automatic Ice

Maker, pages 12-13.

• See Connecting the Water Supply, pages 8-9.

• Turn off water supply and remove kinks. If kinks

cannot be removed, replace tubing.

• Water pressure must be between 35 to 100 pounds

per square inch to function properly. A minimum
pressure of 35 pounds per square inch is
recommended for refigerators with water filters.

• See Temperature Controls, pages 10 and 11. Freezer

temperature should be between 0° to 2° F (-18° to
-17° C) to produce ice.

Do not attempt to free the fountain door by

continuously pressing the dispenser button. Contact
qualified service technician.

• See Temp Alarm, page 11.

• See, Sabbath Mode, page 11.

• To activate audible alarms, refer to page 11.

• See Temperature display on page 10.

WHAT TO DO