beautypg.com

Twin-pipe connection – Atmos Energy INTERCOMBI HE32 User Manual

Page 29

background image

29












Table of Atmos 80/125mm concentric flue equivalent lengths

80/125mm Concentric extension for

balcony outlet

When the free outlet is hindered by an eave, balcony,
gallery or anything else, the concentric terminal must
be extended to at least the front side of the
overhanging part (see diagram).

Maximum equivalent concentric length allowed is 27 metres (Note: Includes an allowance for the

terminal; ie the terminal can be ignored from the equivalent length)

80/125mm concentric components

Equivalent concentric length (M) Remarks

45

0

bend 1.5

87

0

bend 3.0



5.6.5 Twin-pipe connection

1. When using the right-hand air supply, the sealing cap must be moved

to the left-hand air supply.

2. Locate the pipes for the air supply and flue discharge in the supply

and discharge stubs. The in-built silicone sealing ring provides an