beautypg.com

Vertical concentric connection, 80/125mm concentric flue system – Atmos Energy INTERCOMBI HE32 User Manual

Page 28

background image

5.6.3 Vertical Concentric connection

Straight adapters are available for either 60/100mm or 80/125mm systems.
IMPORTANT!
Using the concentric adapter set (see photo), the standard two-pipe
connection can be changed into a concentric connection.
1. Seal the open air supply connections in the appliance with the sealing

cap delivered with the set (item C in photo).

2. Remove the sealing ring around the flue discharge in the appliance, as

shown above.

3. In its place, fit the sealing ring ø 116 x 110 mm (item B in photo).

4. Fit the adapter (item A in photo) on the flue discharge.

5.6.4 80/125mm Concentric flue system

Refer to the Atmos Price List for the full list of flue components.


28