Testing Machine and Electronic Control Functions
F8208801
50
Production Test Cycle Quick Reference Chart
Display
Test Cycle Step
Comments
“S xx”
FEC Control Software
Version
xx is the software version number.
“o xx”
Output Board Software
Version
xx is the software version number.
“Ct 3”
Control Type
xx is the control type.
“oPL”
Control Type
OPL.
“USA”
Control Type
Domestic
“drAn” or “PUnP”
Drain Type
Drain or Pump.
“tEnP”
Temp Sensor
Step skipped if not Temperature Sensor-equipped.
“HEAt”
Heater
Step skipped if not heater-equipped.
“rot”
Rotation Sensor
Step skipped if not Rotation Sensor-equipped.
“L dC” or “L AC”
Door Lock Type
“L dC” if 24 VDC lock or “L AC” if 240 VAC unlock solenoid.
“droP” or “drCL”
Door Status
Door open or closed.
“drUL” or “drLo”
Door Lock Status
Door will lock.
“8.8.8.8.” + all LEDs
Display Test
All display elements are lit.
“PAxx” where xx = 1
through 12
Keypad Test step
Advance after all keypads are pressed.
“A xx”
Top Cover Switch Test
xx is either “CL” for closed or “oP” for open.
“Cxxx” or “Pxxx”
Machine Type/Size
“drxx”
Drive Software Version
Number
xx is the drive software version number. Design 4 models only.
“dPxx”
Drive Parameter Table
Version Number
xx is the drive parameter table version number. Design 4 models
only.
“dt x”
Drive Type Value
xx is the drive type value. Design 4 models only.
“HFIL”
Hot Fill to Low Level
All water outputs turned off when Low Level reached.
“CFIL”
Cold Fill to Low Level
All water outputs turned off when Low Level reached.
“bFIL”
Warm Fill to Low Level
All water outputs turned off when Low Level reached.
“bFIH”
Warm Fill to High Level
All water outputs turned off when High Level reached.
“S1”
Supply #1
“S2”
Supply #2
“S3”
Supply #3
“S4”
Supply #4
Table 16 (continued)