Alliance Laundry Systems PHM1263R User Manual
Page 47
Testing Machine and Electronic Control Functions
45
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Diagnostic (Testing) Mode – Quick Reference Chart
Test Number
Diagnostic Mode
Display
“d001”
Front End Control Software Version # Test
“
S xx”
“d002”
Output Board Control Software # Test
“
o xx”
“d003”
Output Board Water Level Sensor Trim Value
“
txxx”
“d004”
Top Cover Opening Test
“
A oP” or
“
A CL”
“d009”
Door Switch Input Test
“
drCL” or “drOP”
“d010”
Door Lock Input Test
“
drUL” or “drLO”
“d011”
Show Fill Time Test
“
Fxxx”
“d012”
Show Drain Time Test
“
dxxx”
“d013”
Temperature Sensor Display Test
“xxx
F” or “xxxC”
“d014”
Start Pulse Test
“
Stxx”
“d015”
VFD Balance Input Test (Design 1 and 2)
“
bAoP” or “bACL”
“d016”
24 VAC Switch Input Test (Design 1 and 2)
“
ACoP” or “ACCL”
“d017”
VFD Drive Fault Input Test (Design 1 and 2)
“
dFoP” or “dFCL”
“d018”
Frame Balance Switch Input Test
“
FSoP” or “FSCL”
“d019”
VFD Balance Weight Test (Design 1 and 2)
“
bAL”
Drive DC Bus Display Test (Design 4)
“
dCb”
“d020”
Water Purge Test
“
PUrg”
“d021”
Water Leak Detection Test
“
Ld”
“d022”
Drive Software Version Number (Design 4)
“
drxx”
“d023”
Drive Parameter Table Version Number
(Design 4)
“
dPxx”
“d024”
Drive Type Value (Design 4)
“
dt x”
Table 13