beautypg.com

Operational display codes – Aquacal H 100 User Manual

Page 32

background image

8

Selecting Call / Flex Pump Options [CFO] …

( This feature will apply only if the heater installation includes a Call/Flex module.):

A. Depress both the Up and Down arrow keys simultaneously until [CF1] display

appears. Depress the pool/spa key twice, the display will appear.

B. With the

[CFO] (Call Flex Options) code displayed, use the Up or Down arrow keys to

select,

(0) to disable Call Flex Options, (1) to enable the Call Option, or (2) to enable the

Flex Option. Pressing the Pool / Spa key will save the displayed parameter and step to

the menu parameter

[LOC] (Service Lock Code).

9. Fan Speed Control… (This option is not applicable to any current models. If option

present, factory default setting of “80” MUST remain.

OPERATIONAL DISPLAY CODES

Menu Codes Description

Function

[FLO] No water flow

detected

Displayed Code Message: Appears whenever the circulating

pump is off, or when the heater is not receiving correct

water flow.

[OFF] System is off

Displayed Code Message: Appears whenever system is off,

and until temperature set point is raised above 60°°°° F.

[CFI] Celsius Fahrenheit

Selection

Programming Entry Point: Allows temperature read-out to

display either Celsius or Fahrenheit.

[ULC] User Lock Code

Programming Entry Point: When activated steps to the next

menu level [ELC] (enter lock code).

[ELC] Enter Lock Code

Programming Entry Point: Allows end user to select a secret

code so only authorized persons can change heater settings.

[CFO] Call Flex Options

Programming Entry Point: When activated steps to the next

menu level [CFS] (Call or Flex selection)

[Fan]

Two speed fan control Programming Entry Point: This option is not applicable to

any current model; leave at factory default of “80”.

[LOC] Entrance to Service

Menu

Service Entry Point: The [LOC] code allows service

personal the ability to enter a factory code and access

service adjustable parameters in the software that may

require calibration or adjustments. This menu is available

only to authorized Service Personnel.