Winterizing (Continued)

5. Permit all of the water to drain out of the condenser and then, threading

clockwise, replace the plug finger-tight.

6. Reinstall the heater front cover and secure with attaching screws previously

removed.

7. To prevent insects and vermin from entering the plumbing during the

winterized period, partially reconnect the two (2) plumbing connection unions:

couple each union one or two threads; this will permit condensation to drain,

but will prevent most insects and animals from entering the plumbing circuit.

8. Next Season: to ready the heat pump for use, simply re-tighten plumbing

connection unions. Hand-tight is generally sufficient.

Figure 1

CAUTION !

Failure to heed the following can result in

damage to equipment and/or property.

While the plumbing connections are in the winterized condition (not fully

tightenetlunin in gmplral nedpltlltuarwater f ot