6

5. Changing The Pool Temperature Set Point:

A. Using the Pool / Spa key, select the POOL temperature set point. The pool set point

indicator light will confirm your selection by lighting.

B. The pool temperature set point range is adjustable from 60

°F. to 95° F (104

°

F in latest

models). using the Up or Down arrow keys. The desired temperature can be selected

by briefly depressing the arrow keys, or by holding them down to scroll the temperature

up or down.

6. Changing The Spa Temperature Set Point:

A. Using the Pool / Spa key, select the SPA temperature set point. The spa set point

indicator light will confirm your selection by lighting.

B. The spa temperature set point range is adjustable from 60

°F to 104°F by using the Up

or Down arrow keys. The desired temperature can be selected by briefly depressing

the arrow keys, or by holding them down to scroll the temperature up or down.

7. Selecting Between °°°°F And °°°°C:

A. Depress both the Up and Down arrow keys simultaneously until

[CF1] (Celsius /

Fahrenheit) code appears.

B. With the

[CF1] code displayed, pressing either the Up or Down arrow key will

display either a

(1) or (0). Select (1) for Fahrenheit temperature display or (0) for Celsius

temperature display. Once the desired temperature display has been selected, not

depressing any buttons for 15 seconds will allow the control to save the selection and

return to the normal operating mode. Pressing the Pool / Spa key will also save the

selection and step to the next menu parameter

[ULC] (User Lock Code).

8. User Lock Code Option [ULC] :

This Option Explained:

Heat pumps are shipped from the factory with the ULC option disabled. Enabling the ULC

function permits the heat pump owner to restrict access to the unit controls. With the ULC

option enabled, unless the correct ULC lock code number is entered, changes to

programming are not possible (I.e.: Altering temperature set points, Pool/Spa selection, C/F

display changes, etc., will not be possible). The ULC option can be thought of as an

electronic lockable cover for the controls.

A. Selecting ULC Option:

1) Depress either of the Up

or Down arrow keys; if [000] is displayed, the ULC

feature is already enabled. If

[000] displays, proceed to number “6” of this section;

otherwise, see number “2” below;

2) Depress both the Up and Down arrow keys simultaneously until the

[CF1]

display appears;

3) Depress the pool/spa key once, the

[ULC] display will appear;