Asus RS100-E5-PI2 User Manual
Page 120

6-26
Chapter 6: RAID Configuration
3. When prompted, use the arrow keys to select Yes from the Consistency
Check dialog box, then press
the drive consistency.
A progress bar appears on screen.
4. While checking the disk consistency, press
options.
• Stop: Stops the consistency check. The utility stores the percentage
of disk checked, When you restart checking, it continues from the last
percentage completed rather than from zero percent.
• Continue: Continues the consistency check.
• Abort: Aborts the consistency check. When you restart checking, it
continues from zero percent.
5. When checking is complete, press any key to continue.
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
SPACE-(De)Select, F10-Check Consistency
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 4 64 KB ONLINE
Virtual Drives
Virtual Drive 0
Consistency Check?
Yes
No
Select VD
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
SPACE-(De)Select, F10-Check Consistency
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 4 64 KB ONLINE
Virtual Drives
Virtual Drive 0
CC Under Process
VD 0 Consistency Check. Press Esc to Abort.
¦ 85 % Completed
The Data On The Drives Is Inconsistency. Repair Done!