4 checking the drives for data consistency, Checking the drives for data consistency -25, Using the check consistency – Asus RS100-E5-PI2 User Manual
Page 119

ASUS RS100-E5-PI2
6-25
6.3.4
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the Objects > Adapter
menu.
The Check Consistency command is available only for virtual drive included in
a RAID 1 set.
Using the Check Consistency
To check data consistency using the Check Consistency command:
1. From the Management Menu, select Check Consistency, then press
2. The screen displays the available RAID set(s) and prompts you to select the
virtual drive to check. Press the
the Virtual Drive selection, then press
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
CC Of VD(s)
LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007
SPACE-(De)Select, F10-Check Consistency
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Select VD
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 154494MB 2 64 KB ONLINE
Virtual Drives
Loical Drive 0