3. STEAM DAMPER AIR SYSTEM CONNECTIONS

The MLS-75 is manufactured with a pneumatic (piston) damper system which requires an external
supply of compressed air. The air connection is made to the steam damper solenoid valve which is
located at the rear inner top area of the dryer just in front of the electric service relay box.

a. Air Requirements

b. Air Connection

Air connection to system --- 1/8-inch N.P.T.

c. No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 psi must be

provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just
before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved

.

Compressed Air Supply

Air Pressure

Normal

80 psi

Minimum Supply

70 psi

Maximum Supply

90 psi