beautypg.com

Type of gas – American Dryer Corp. ML-75HS User Manual

Page 32

background image

28

2. TECHNICAL GAS DATA

a. Gas Specifications

b. Gas Connections:

Inlet connection ------------ 3/4" inch N.P.T.

Inlet supply size ------------ 3/4" inch N.P.T. (minimum)

Btu/hr input (per dryer) --- 200,000

1) Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure

must be consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water

column pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator

blocked open so that the gas pressure must be regulated upstream of the dryer. The

pressure measured at each gas valve pressure tap must be a consistent 10.5 inches

water column. There is no regulator or regulation provided in an L.P. dryer. The water

column pressure must be regulated at the source (L.P. tank) or an external regulator

must be added to each dryer.

* D.M.S. (Drill Material Size of equivalents are as follows:)

Natural Gas ................... # 29 = .1360"

Liquid Propane Gas ...... # 47 = .0785"

Type of Gas

Natural

Liquid Propane

Manifold Pressure

3.5 inches W.C.

10.5 inches W.C.

Inline Pressure

6.0 - 12.0 inches W.C.

10.5 inches W.C.

Type of Gas

L.P.

Conversion

Kit Part
Number

Natural

Liquid Propane

Model

Number

BTU Per

Hour

Rating

Qty.

D.M.S.*

Part

Number

Qty.

D.M.S.*

Part

Number

MLG-75

200,000

4

#29

140820

4

#47

140805

881231