beautypg.com

American Dryer Corp. ML-75HS User Manual

Page 27

background image

23

Single-Phase (1Ø) Electrical Connections Leads

Black

+

Positive

White

+

Neutral

Green

+

Ground

or

L2

Actual electrical wire connections are made to the L1 and L2 terminals of the motor contactor located in

the rear service box mentioned above. The ground connection is also made to the copper lug also provided in this

box.

If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/pigtail (wire

size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both

cases, a strain relief must be installed where the wiring enters the dryer.

2) 3 Phase (3 Ø) Wiring Connections / Hookup "NON-REVERSING MODELS ONLY"

The electrical connections on ALL three-phase (3 Ø) gas and steam dryers are made into the rear service box

located at the upper left area of the dryer. Electrical connections for electrically heated dryers are made in the

electric oven area located at the upper rear area of the dryer.

NOTE: A CIRCUIT SERVING EACH DRYER MUST BE PROVIDED.

If local codes permit, power to a gas or steam dryer can be made by the use of a flexible U.L. listed power cord/

pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker

panel. In all cases, a strain relief must be installed where the wiring enters the dryer.