beautypg.com

Sleep mode, Proximity sensor – ATN MK 6600 User Manual

Page 5

background image

3

4

SLEEP MODE

One of the greatest new features that your Smart scope has is the SLEEP mode. This feature has

been designed to considerably extend the period of scope’s functioning, to set the scope to memo-

rize your initial settings and endure battery’s life (by settings we mean only digital settings which

include brightness of the tube, brightness of the reticle, and magnitude of the IR.) Here is a descrip-

tion as to now the sleep mode functions:
The scope will automatically shut down if it does not sense any activity (i.e. pressing any of the but-

tons or simply moving the scope back and forth away from your face) for 20 minutes. When activat-

ing the sleep mode the scope will first warn you by turning off the reticle for 10 seconds. If you intend

is to keep using the scope simply touch any key and the scope will reactivate.
One of the reasons for the SLEEP mode being programmed into your scope is to keep the light

intensifier tube and batteries safe in case you forget to turn your unit off. If you notice that the reticle

turned off after 20 minutes just push the SL button and the scope will return to its previous settings.
To put your scope in the “SLEEP” mode any time, just push the SL button and “-” simultaneously.

Push SL to return to previous settings and the SMART scope will remember them. This feature will

come very handy, if you are waiting for game to come: you can prepare all of the settings, place

the unit in SLEEP mode and activate it precisely when you need it. To disable the proximity sensor

press SL and “+” simultaneously. In order to turn the proximity sensor back on, press SL and “+”

simultaneously again.

NOTE: The scope is capable of running in SLEEP mode for more than 10 (ten) days and is ready for

use at any moment. Remember, you don’t have to turn the unit off while you are using it (“Smart” sight

remembers all the settings). Use the master ON/OFF switch only to store the scope.

PROXIMITY SENSOR

If you turn the proximity sensor on it will activate the

scope when brought to your eye. The proximity sensor

disables the scope when you take it away from your

face. This feature has been introduced to prolong the

life of the tube and the battery.
To turn the proximity sensor on press SL and + at the

same time.
To disable the proximity sensor press SL and + at the

same time again.

NOTE: Proximity sensor would not turn on automati-

cally after master power has been switched on.

Proximity sensor