beautypg.com

Loopstar, Ethernid, Metr onid – ADC LoopStar MetroNID User Manual

Page 9: Ethernid™ – loopstar, Metronid, Specifications

background image

9/08

107033AE

LoopStar

®

EtherNID

LoopStar

®

Metr

oNID

LoopStar

®

EtherNID™ – LoopStar

®

MetroNID™

ADC's network interface devices for Ethernet and IP networks

9

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Specifications

HArDWAre & PerForMAnce

Pure Hardware Data-Path

• inline transparent performance (all packet sizes):

Throughput:

wire-speed (1000 Mbps at 100% utilization)

intrinsic Pass-through Traffic Latency:

< 3.3 μs

intrinsic Pass-through Traffic Jitter:

< 0.1 μs

intrinsic Latency for intelligent Loopback: < 0.8 μs
intrinsic Jitter for intelligent Loopback:

< 0.1 μs

 • High-accuracy, hardware-assisted performance measurements with 1μs resolution.

Integrated Management

• SnMP v1, v2c

• radius Authentication

• Secure Web Gui via SSL

• Secure cLi via SSH

• Management vLAn

• 802.3ah eFM oAM

• configuration import/export • FTP, TFTP, HTTP, HTTPS
• nTP client (or source)

• remote and Local Syslog

• DnS client

• DHcP client

• in-band remote management over the ethernet customer line via network & client-side interface
• Local Management craft port: 10/100BaseT rJ-45 connector
• Serial rS-232 Management port: rJ-45 connector
• Zero-Touch provisioning to oSS systems & echovault™ SLA eMS

Redundant Power, Connectivity & Timing

Power:

External AC/DC adapter (120-240Vac auto-sensing, 50-60Hz), 5VDC input to unit

Dual (A/B) -48Vdc Central Office Supply inputs

Power Consumption:

5-8 watts

Cooling:

Convection cooled (no fans)

Redundant Power:

Transparent fail-over bypass on electrical-to-electrical models

Connectivity:

Dual Protected Uplink allows two redundant connections on the network side for

increased reliability

(1)

GPS:

Optional embedded GPS with front-panel SMA input

(1)

Physical Specifications

Dimensions (H x W x D):

1.60” x 5.34” x 5.80” (4.06 cm x 13.56 cm x 14.73cm)

Weight:

625 g or 1.37 lb

MTBF:

52-66 years (at 25 degree C ambient)

Mounting Options:

Desktop, Wall-mount, Rack-mount:1 or 2 units side-by-side in 1U

EtherSHELF™: High density, 12-unit, 19” Central Office shelf in 4U

(23” adapter available)

Regulatory and Certification

• iec 60950

• neBS Level 3

• Fcc Part 15 class A

• MeF9 Service certification

• industry canada cS-03

• MeF14 Traffic Management

• ce Mark

Environmental

Standard operating temperature:

-5º to +65°C (23º to 149ºF)

Hardened operating temperature (-H):

-40º to +65°C (-40º to 149ºF)

 Storage temperature:

-40º to +70°C (-40º to 149ºF)

 Operating/storage humidity:

5-95 %RH non-condensing

(1) Available on MetroNID™ models only

This manual is related to the following products: