Error and warning codes, When you have finished, When error codes appear – Sony HT-7200DH User Manual

Page 31: Error codes and remedies

background image

31

US

Ge
tting Star

te

d

The table below shows the display when
measurement starts.

* The corresponding speaker indicator lights

up in the display during measurement.

4

Measurement ends.

“COMPLETE” appears on the display
and the settings are registered.

When you have finished

Disconnect the optimizer microphone from the
AUTO CAL MIC jack.

Notes

• Auto Calibration cannot detect the sub woofer.

Therefore, all sub woofer settings will be
maintained.

• If you have repositioned your speakers, we

recommend that you perform Auto Calibration
again to enjoy the surround sound.

Tips

• When Auto Calibration starts:

– Stand some distance from the speakers and the

listening position to avoid measurement failure.
This is because test signals are output from the
speakers during measurement.

– Avoid making noise to get a more accurate

measurement.

• During the measurement process, the Auto

Calibration function will be canceled when you do
the following:
– Press ?/1 or MUTING.
– Press the input buttons or turn INPUT

SELECTOR on the receiver.

– Change the volume level.
– Connect the headphones.
– Press AUTO CAL again.

When error codes appear

When an error is detected during Auto
Calibration, an error code will appear on the
display cyclically after each measurement
process as follows:
Error code

t blank display t (error code t

blank display)

a)

t PUSH t blank display

t ENTER

a)

Appears when there are more than one error code.

To rectify the error

1

Record down the error code.

2

Press .

3

Press ?/1 to turn off the receiver.

4

Rectify the error.
For details, see “Error codes and remedies”
below.

5

Turn on the receiver and perform Auto
Calibration again (page 30).

Error codes and remedies

Measurement for

Display

Environment noise
level

NOISE.CHK

Speaker connection

MEASURE and SP
DET. appears
alternately*

Speaker level

MEASURE and GAIN
appears alternately*

Speaker distance

MEASURE and
DISTANCE appears
alternately*

Error and warning codes

Error code

Cause and remedy

ERROR 10

The environment is too noisy.
Make sure the environment is quiet
during Auto Calibration.

ERROR 11

The speakers are placed too near
the optimizer microphone. Place
your speakers further away from
the optimizer microphone.

ERROR 12

None of the speakers are detected.
Make sure that the optimizer
microphone is connected properly
and perform Auto Calibration
again.

ERROR 20

Front speakers are not detected or
only one front speaker is detected.
Check the front speakers
connection.

ERROR 21

Only one surround speaker is
detected. Check the surround
speakers connection.

continued