beautypg.com

J. shutdown instructions, K. operating instructions – American Dryer Corp. MDG-120PVV User Manual

Page 31

background image

113395 - 6

Maytag Co.

29

J. SHUTDOWN INSTRUCTIONS

If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:

1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2. Discontinue the gas or steam supply:

a. GAS MODELS – discontinue the gas supply.

1) SHUT OFF external gas supply shutoff valve.

2) SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.

b. STEAM MODELS – discontinue the steam supply.

1) SHUT OFF external (location furnished) shutoff valve.

K. OPERATING INSTRUCTIONS

NOTE: Before attempting to start the dryer make sure that the main door is closed and the lint drawer

is securely in place.

1. To start the dryer:

a. Microprocessor Controller (Computer) Dryers (refer to user’s manual included with dryer).

b. Dual Timer Dryer Models:

1) Select drying time and cool down time desired.

a) Turn heat timer clockwise (CW) to desired time (i.e., 1 minute to 60 minutes).

b) Turn cool down timer clockwise (CW) to desired time (i.e., 0 minutes to 15 minutes).

2) Select drying temperature.

3) Push “Start” button.

Dryer will now start.

4) To stop dryer, open the main door.