31

DC output voltage

18.0 ~ 20.0

Constant output

7.9A

Dynamic Output Characteristics
Start-up time

3 sec. (@115 Vac and 230Vac full load)

Hold up time

5ms min. (@115 Vac input, full load)

Over Voltage Protection
(OVP)

25V

Short circuit protection

Output can be shorted without damage, and auto recovery

Electrostatic discharge
(ESD)

15kV (at air discharge)
8kV (at contact discharge)

Dielectric Withstand Voltage
Primary to secondary

4242 Vdc for 1 second-

Leakage current

60uA at 240Vac/60Hz

Regulatory Requirements

1. FCC class B requirements (USA)
2. VDE class B requirements (German)
3. VCCI classII requirements (Japan)

Power Management

ACPI Mode

Power Management

Mech. Off (G3)

All devices in the system are turned off completely.

Soft Off (G2/S5)

OS initiated shutdown. All devices in the system are turned
off completely.

Working (G0/S0)

Individual devices such as the CPU and hard disk may be
power managed in this state.

Sleeping State (S3)

CPU Power Down
VGA Power Down
PCMCIA Suspend
Audio Power Down
Hard Disk Power Down
Super I/O Power Down

Sleeping State (S4)

Also called Hibernate state. System saves all system
states and data onto the disk prior to power off the whole
system.

Environmental Requirements

Item

Specification

Temperature
Operating

+5 ~ +35°C

Non-operating

-20 ~ +65°C (storage package)

Humidity
Operating

10% ~ 90% without condensation

Altitude

Operating sea level 0 to 10,000ft
Storage sea level 0 to 40,000ft

AC Adapter

Item