4. Steam Damper Air System Connections

The EURO-35 is manufactured with a pneumatic (piston) damper system which requires an external supply
of compressed air. The air connection is made to the steam damper solenoid valve which is located at the
rear inner top area of the dryer just in front of the electric service relay box.

a. Air Requirements

There is no air requirement for dryers with the Electromechanical Steam Damper Option.

b. Air Connection

Air connection to system --- 1/8-inch N.P.T.

c. Air Regulation

No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 psi (552 kPa)
must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed
air line just before the dryer connection. This is necessary to insure that correct and clean air pressure
is achieved.

C

OMPRESSED

A

IR

S

UPPLY

A

IR

P

RESSURE

Normal

80 psi

552 kPa

Minimum Supply

70 psi

483 kPa

Maximum Supply

90 psi

621 kPa