American Dryer Corp. EURO-35 User Manual

Page 26

background image

22

S

INGLE

-P

HASE

(1

Ø

)

E

LECTRICAL

C

ONNECTIONS

L

EADS

Black

+

Positive

White

-

Neutral

Green

Ground

or

L2

Actual electrical wire connections are made to the L1 and L2 terminals of the motor contactor
located in the rear service box mentioned above. The ground connection is also made to the copper
lug also provided in this box.

If local codes permit, power to the dryer can be made by the use of a flexible power cord/pigtail (wire
size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker
panel. In both cases, a strain relief must be installed where the wiring enters the dryer.

2) 3-Phase (3ø) Wiring Connections/Hookup (for Non-Reversing Models Only)

The electrical connections on ALL 3-phase (3ø) gas and steam dryers are made into the rear service
box located at the upper left area of the dryer. Electrical connections for electrically heated dryers
are made in the electric oven area located at the upper rear area of the dryer.

NOTE: A CIRCUIT SERVING EACH DRYER MUST BE PROVIDED.

If local codes permit, power to a gas or steam dryer can be made by the use of a flexible power cord/
pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the
service breaker panel. In ALL cases, a strain relief must be installed where the wiring enters the
dryer.