beautypg.com

Euro-35 (e, Lectric – American Dryer Corp. EURO-35 User Manual

Page 24

background image

20

b. Electric Models ONLY

IMPORTANT: Figures shown are for Non-Reversing Models ONLY. For reversing models contact

the factory.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is

affixed to the back side of the upper/top control door. In the case of 208 VAC or
240 VAC, the supply voltage must match the electric service specifications of
the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically VOID THE
WARRANTY.

NOTE: 3-Phase (3ø) figures shown are for 3-wire service ONLY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or

obligation.

APPROX.

AMP

DRA

W

EURO-35 (E

LECTRIC

)

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according
to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.

APPLIED VOLTAGE/PHASE

Kw

208/1ш

240/1ш

208/3ш

240/3ш

380/3ш

416/3ш

460/3ш

30

--

--

88

77

--

45

41

33

--

--

---

--

53

--

--

36

--

--

104

92

--

53

48

40

--

--

--

--

--

59

--