beautypg.com

American Dryer Corp. EURO-35 User Manual

Page 31

background image

27

2. Technical Gas Data

a. Gas Specifications

b. Gas Connections

Inlet connection ----------- 3/4” inch N.P.T.
Inlet supply size ----------- 3/4” inch N.P.T. (minimum)
Heat input (per dryer) ---- 200,000 Btu/Hr (50,400 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must
be
consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches water
column (W.C.) - 29.9 mb - pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches water column (26.1 mb). There is no regulator
or regulation provided in an L.P. dryer. The pressure must be regulated at the source (L.P. tank) or
an external regulator must be added to each dryer.

T

YPE OF

G

AS

Natural

Liquid Propane

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

Inline Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

Shaded areas are stated in metric equivalents

* Measured at gas valve pressure tap when the gas valve in on.

T

YP E OF

G

AS

L.P.

Conversion Kit

Part Number

ADC

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty. D.M.S.*

Part

Number

Qty. D.M.S.*

Part

Number

EURO-35

200,000 Btu/Hr

50,400

4

#29

140820

4

#47

140805

490453

Shaded area is stated in metric equivalent

* D.M.S. (Drill Material Size) equivalents are as follows:

Natural Gas ............... #29

= .1360" (3.454mm)

Liquid Propane Gas .. #47

= .0785" (1.994mm)