beautypg.com

Accessories – Karcher KM 90-60 R Bp User Manual

Page 27

background image

-

11

Î

Check tension, wear and damages on
the V-belt of the sweep roller drive.

Î

Tighten the V-belt at the screw if neces-
sary.

Î

Check tension, wear and damages on
the V-belt of the sweep roller drive.

Î

Check hose at the suction blower for
tightness.

1 Automotive flat plug fuse
2 Pole fuse
– Replace the automotive flat plug fuse

with the following rating: 1 A (F2) - vac-
uum pump

Î

Replace defective fuse.

Î

Replace defective fuse.

Note:A defective pole fuse may only be re-
placed by a Kärcher service technician or
an authorised expert. If this fuse is defec-
tive, check the usage conditions and the
entire control system.

Check suction blower

Replacing the fuse

Pole fuse

Accessories

Side brushes

6.905-626.0

With standard bristles for indoor and out-
door areas.

Standard sweep roller 4.762-430.0
Resistant of wear and moisture. Universal
bristles for inside and outside cleaning.

Roller-brush, soft

4.762-442.0

With natural bristles especially for fine
dust sweeping on smooth indoor floors.
Not resistant to wetness; not for abrasive
surfaces.

Dust filter

6.414-576.0

Roller brush, antistatic

4.762-441.0

Carpet sweeping unit 2.641-665.0

27

EN