beautypg.com

Technical specifications – Karcher HDS-E 8-16-4 M 36 KW User Manual

Page 29

background image

– 12

Technical specifications

HDS-E 8/16-

4M 12kW

HDS-E 8/16-

4M 24kW

HDS-E 8/16-

4M 36kW

Main Supply
Voltage

V

400

420

400

420

400

420

Current type

Hz

3~ 50 3~ 50 3~ 50 3~ 50 3~ 50 3~ 50

Connected load

kW

17,5

17,5

29,5

29,5

41,5

41,5

Protection (slow)

A

32

32

50

50

63

63

Type of protection

--

IPX5

IPX5

IPX5

IPX5

IPX5

IPX5

Protective class

--

I

I

I

I

I

I

Water connection
Max. feed temperature

°C

30

30

30

Min. feed volume

l/h (l/min)

1000 (16,7)

1000 (16,7)

1000 (16,7)

Max. feed pressure

MPa
(bar)

0,6 (6)

0,6 (6)

0,6 (6)

Performance data
Water flow rate

l/h (l/min)

360-760

(6,0-12,7)

360-760

(6,0-12,7)

360-760

(6,0-12,7)

Operating pressure of water (using stand-
ard nozzle)

MPa
(bar)

3,3-16,0

(33-160)

3,3-16,0

(33-160)

3,3-16,0

(33-160)

Max. excess operating pressure (safety
valve)

MPa
(bar)

20,5 (205)

20,5 (205)

20,5 (205)

Max. operating temperature of hot water °C

85

85

85

Switch-off temperature hot water

°C

98

98

98

Operating temperature during continuous
operation with 15 °C input temperature

°C

30

45

57

Detergent suck in

l/h (l/min)

0-30 (0-0,5)

0-30 (0-0,5)

0-30 (0-0,5)

Heating output

kW

12

24

36

Max. recoil force of trigger gun

N

37,2

37,2

37,2

Nozzle size

--

045

045

045

Values determined as per EN 60355-2-79
Noise emission
Sound pressure level L

pA

dB(A)

67

67

67

Uncertainty K

pA

dB(A)

3

3

3

Sound power level L

WA

+ Uncertainty K

WA

dB(A)

85

85

85

Hand-arm vibration value
Hand spray gun

m/s

2

4,5

4,5

4,5

Spray lance

m/s

2

1,9

1,9

1,9

Uncertainty K

m/s

2

0,3

0,3

0,3

Fuel
Amount of oil

l

0,75

0,75

0,75

Oil grade

--

SAE 90

SAE 90

SAE 90

Dimensions and weights
Length x width x height

mm

1330 x 750 x

1060

1330 x 750 x

1060

1330 x 750 x

1060

Typical operating weight

kg

190

192

197

Detergent Tank

l

10+20

10+20

10+20

Total boiler capacity

l

50

50

50

Boiler capacity of pre-heating chamber

l

18

--

--

29

EN