Menus and DMX channel configuration for Elektralite UV & WW eyeBall
1、STATIC → UV (or WW) 0-255 dimming level
STROBE 0-20 flashes
Static mode allows the fixture to be on without a controller.
2、AUTO → EFFECT 1
EFFECT
2
EFFECT
3
Auto is automatic in built programs. There are 3 programs.
3、 RUN → DMX512
SLAVE
The fixture can be run in DMX mode or as a slave fixture.
4、ADDRESS → DMX: 1-512
ID. : 1-255
The fixture can run in DMX. (Make sure the id address is set at 0 for DMX to work)
The fixture can run in any of 255 id addresses.
5、PERSONALITY → STAG1 (Stage 1)
STAG2 (Stage 2)
6、SETTINGS → DIMMER (Curve)→ 0-4
There are 4 choices.
RESET
→ PASSWORD [****] →
The reset password is accessed by pressing the up/down keys in the
following order….UP DOWN UP DOWN then press enter
7、FAN
→
8、KEY →
The key is a lock on the display. So no one can interfere with the fixture.
To turn off the key, the password will need to be entered. See above for password details.
Factory Reset:
1. DMX ADDRES=001
5. FAN = AUTO
2. ID ADDRES=001
6. DIMMER = 001
3. RUN = DMX512
7. KEY = OFF
4. PERSONALITY = STAG1