Operation, Weekly cleaning, Daily cleaning – AccuTemp EVOLUTION ELECTRIC STEAMER User Manual
Page 17: Cleaning - connectionless

MP4008-0910
EVOLUTION STEAMER OWNERS MANUAL
Page 15
WEEKLY CLEANING
1) Close the drain valve and add 1 cup (8 ounces or 0.24 liters) of white vinegar to the
cooking chamber and fill with approximately 2½ gallons of tap water , shut the door and
turn the steamer on.
2) After 15 minutes, turn the steamer off and allow the steamer to cool. Open the drain
valve and allow the cooking chamber to drain completely.
3) To rinse close the drain valve, fill with approximately 2½ gallons tap water , close the
door and start the steamer Cook Mode. Let it run for 15 minutes, turn the steamer off
and allow the steamer to cool. Open the drain valve and allow the cooking chamber to
drain completely.
4) Remove the pan racks, steam collector and steam distributor for cleaning. Clean the
water sensors with a non-metallic cleaning pad. Wipe the inside of the cooking chamber,
water sensors, pan rails (Fig. 16),steam distributor (Fig. 16), steam collector (Fig. 16).
5)
Install the steam collector first, resting the steam distributor on top of the collector align
the 4 retaining fasteners and hand tighten and then install the pan rails. Leave door
open overnight.
DAILY CLEANING
1) Turn the steamer off and wait for the steamer to cool.
2) Open the drain valve and allow the cooking chamber to drain completely. Remove
the pan rails (Fig. 16) and steam collector. Wipe the inside of the cooking chamber,
water sensors, pan rails and steam collector with a clean cloth.
3)
Install the steam collector and pan rails. Once the water in the drain pan has
sufficiently cooled empty the drain pan wipe down and replace . Leave the door
open overnight.
CLEANING - CONNECTIONLESS
Fig. 16
Steam Generator
Steam Distributor
Pan Rail
OPERATION