TROUBLESHOOTING (continued)

Control Board LEDs

The control Board has three on board LEDs (Figure

5) to determine the status of the unit and to assist in

troubleshooting.
Green (Diagnostic): This LED should be off in normal

operation. If any of the 5 potential faults are detected by

the Control Board, this LED will repeatedly blink either 1

through 5 times with a 2-second pause in between (see

the

Green LED Blink Codes section below).

Yellow (Audio): When lit, this LED indicates that the

Control Board is supplying approximately 10-15 VDC

to the audio signal. The audio signal should sound with

this LED is lit.
Red (Heat): When lit, this LED indicates that the

Control Board is calling for heat by supplying VDC to

terminals 3(+)4(-) of the Solid State Relay. When off,

this LED indicates that the grill Platen is up to operating

temperature and satisfied.

NOTE: During heat mode, this Red LED is very dim,

so it may be difficult to verify if the Control Board

is or is not calling for heat. It is recommended that

you observe the small round green LED on the

Solid State Relay (Figure 6) for mode and diagnos-

tic purposes. When the green LED on the Solid

State Relay is on, it means that the Control Board is

calling for heat. When off, it means that the Control

Board is NOT calling for heat. Typically, the VDC at

the Solid State Relay will be less than 1.0 VDC when

measured, but may vary because of different qual-

ity VOMs. Therefore, it is recommended that you do

NOT attempt to measure the VDC at the Solid State

Relay for diagnostic purposes.

Green LED Blink Codes

Number of Blinks

Cause(s)

Unit’s State and Resolution

The Green LED blinks

on and off 1 time, paus-

es for 2 seconds, and

repeats.

The EEPROM memory on the Control

Board is corrupted.

In this state, the unit turns off the control Signal to the Solid

State Relay and disables all front buttons and lights. The

unit will not heat up. This continues until the defaults are

reloaded into memory. To reload defaults, turn the unit off,

press and hold the

TIME 2 button, turn the unit on, and

release the button.

The Green LED blinks

on and off 2 times,

pauses for 2 seconds,

and repeats.

The ambient temperature within the

control compartment has exceeded

155ºF (68ºC). Verify that there is

proper air ventilation all around the unit

and that it is not near a significant heat

source.

In this state, the unit turns off the control signal to the

Solid State Relay and disables all front buttons and lights.

The unit will not heat up. This continues until the ambient

temperature within the electrical compartment drops below

140°F (60°C) and the unit is turned off and back on.

The Green LED blinks

on and off 3 times,

pauses for 2 seconds,

and repeats.

Open or disconnected Thermocouple.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and lights. The

unit will not heat up. This continues until the Thermocouple

is reconnected or replaced, and the unit is turned off and

back on.

The Green LED blinks

on and off 4 times,

pauses for 2 seconds,

and repeats.

The supply voltage to the unit is below

160 VAC or above 265 VAC.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and lights. The

unit will not heat up. This continues until the supply voltage

is within the proper limits and the unit has been turned off

and back on.

The Green LED blinks

on and off 5 times,

pauses for 2 seconds,

and repeats.

The 50/60 Hz signal has been lost

due to a disconnected or an open

wire harness/wiring on the AC Isolator

Board, or from the AC Isolator Board to

the Control Board.

In this state, the unit turns off the control signal to the Solid

State Relay and disables all front buttons and lights. The

unit will not heat up. This continues until the 50/60 Hz sig-

nal is reapplied and the unit is turned off and back on.

HEAT

BUZZ

STATUS

CR4

CR3

CR5

YELLOW

GREEN

RED

R17

R20

R18

Figure 5. Control Board

LEDs

Figure 6. Solid State

Relay

R

PRODUCT SERVICE