beautypg.com

American Standard BERWICK M968641 User Manual

Page 4

background image

M 9 6 8 6 4 1 R E V. 1 . 2

1

4

10

TEST INSTALLED FITTING

With HANDLE (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3).

Operate HANDLE (1) to flush water lines thoroughly.

Replace AERATOR (3).

3

CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.

Check that DRAIN STOPPER (5) makes a good seal

and retains water in Sink. If DRAIN STOPPER (5)

does not seal properly, please refer to Troubleshooting

section in these instructions.

Release POP-UP KNOB (4) down and check all drain

connections and "P" trap for leaks. Tighten

if necessary.

12

4

OFF

ON

HOT

COLD

5

“P” TRAP

WASTE

OUTLET

2

2

CARE INSTRUCTIONS:

1

2

2.5mm HEX KEY

3

8

4

A

B

D

5

6

REMOVE

INSTALL

7

10

11

SERVICE

To remove or replace cartidge:

To adjust HOT LIMIT SAFETY STOP:

Turn valve to OFF position.

Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).

Pull off HANDLE (3) and CAP (4).

Unthread CARTRIDGE NUT (5) and remove.

Pull out CARTEIDGE (6).

Inspect CARTRIDGE (6) and O-RINGS (7) for debris and

clean if necessary.

Clean MANIFOLD (8) and rinse clean.

Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8).

Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).

If spout drips, operate handle several times from OFF to ON and

HOT to COLD position. Do not force - handle turns only 90˚.

Turn off hot and cold water

supplies before beginning.

CAUTION

By restricting HANDLE rotation and limiting the amount of hot

water allowed to mix with the cold, the HOT LIMIT SAFETY

STOP (9) reduces risk of accidental scalding. To lower the

maximum hot water temperature of your faucet, all you need

to do is adjust the setting on the HOT LIMIT SAFETY STOP (9).

Note: The HOT LIMIT SAFETY STOP (9) is set at the maximum

hot temperature setting from the factory. Fig. A.

ADJUST HOT LIMIT SAFEYT STOP

Remove HANDLE ASSEMBLY (3), CAP (4) and CARTRIDGE NUT (5).

Set the CARTRIDGE STEM (10) to the OFF position and rotate it

clockwise until stops.

Fig. B.

Rotate the CARTRIDGE STEM (10) counter-clockwise to a colder

setting mark in the HOT LIMIT SAFETY STOP (9).

Fig. C.

Lift up the HOT LIMIT SAFETY STOP (9) and rotate it to coincide

again with the stop in the base of the CARTRIDGE STEM (10).

Fig. D.

Replace the HOT LIMIT SAFETY STOP (9).

Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).

GEAR

GEAR

GEAR

10

9

9

C

10

9

+HOTTER

SETTING

MARKS

COLDER

GEAR

10

9

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A