ALARM FEATURE “C” PROGRAMMING:

1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.

2. Push the Valet switch 7 times and hold on the 7

th

push until Three

chirps with a long chirp is heard then release the valet switch. You are
now in the Alarm feature ‘C’ programming mode.

3. Press and hold the transmitter

button for two seconds to enter

shock sensor program mode.

Press
Transmitter

Button

One Chirp /
LED one pulse

Factory Default Setting

Two Chirps /
LED two pulse

1

Shock Sensor Program Mode


ADJUST AND TEST THE SENSITIVITY LEVEL OF THE SHOCK
SENSOR

1. Turn the Ignition switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch7 times holding in on the7th push. Three chirps

with a long chirp will be heard. Release the valet switch. You are now
in the Alarm feature ‘Shock Sensor’ programming mode.

3. Press and hold

button for 2 seconds. One long siren chirp will

indicate the unit is ready to accept adjustments of the shock sensor.

4. Press

button on the transmitter once. This will decrease sensitivity

level by one. Each time the button is pushed and a decrease is made
the siren/horn chirp will respond with [1] chirp. Two chirps indicate the
minimum sensitivity. Warn away & full trigger will be deleted when
minimum sensitivity is selected. Shock sensor OFF

5. Press

button on the transmitter once. This will increase sensitivity

level by one. Each time an increase is made the siren/horn chirp will
respond with [1] chirp. Two chirps indicate the maximum sensitivity.

6. Hit the bumper or strong metal part of the vehicle to test the threshold

level of the sensor.

a). Activate the warn-away (first stage the shock sensor), the siren will
emit a short chirp.
b). Activate the full alarm (second stage the shock sensor), the siren
will emit a long chirp.

7. When you are satisfied with the setting, press the

button to lock in

the adjustment. One long siren chirp will indicate the unit has locked in
the adjustment.

Note: If 30 seconds of inactivity expires or you turn ON the ignition during

of above steps, the unit will exit the program mode and return to the
disarmed mode. Three long chirps will confirm exit.