Overview

6

Link Test Switch

The Link Test switch is a fast and easy way for you to test the integrity of the
fiber optic connections to the fiber optic ports on the media converter (see
Figure 4). The AT-MCF6xx unit has one Link Test switch which is used to test
all six fiber optic ports on the unit. The AT-MCF12xx unit has two Link Test
switches; one switch is used to test the fiber optic ports in channels 1 through
6 and the second switch is used to test the fiber optic ports in channels 7
through 12 on the unit.

Figure 4 Link Test Switch

The Link Test switch is used after installation to verify that the unit and
connections are operating properly, or whenever you need to test the fiber
optic ports or the integrity of the fiber connections to the nodes connected to
the ports.

The LED next to the Link Test switch indicates the operating mode of the
fiber optic ports. If the Test LED is lit amber, a link test is being performed on
the fiber optic ports associated with the switch. The section “Troubleshooting”
on page 23
contains instructions for performing a link test. Refer to Table 2,
“Power Supply and Link Test Switch LEDs,” on page 3 fo
r the Link Test
Switch LEDs.

Note

The media converter will not pass network data when the Link Test
switch is in the Link Test position. For normal network operations, the
switch must be set to the Normal setting.

RESET

7-12 LINK TEST

NORM

TEST

MCF12SC

10Base-TX/FX Media Converter

MANAGEMENT

LNK

REC

STATION

HUB

OR

10Base-T

RS232

P O W E R

BCKP

MAIN

Ready

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

7

8

9

10

11

12

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

Tx

Rx

T-LNK

F-LNK

Active

1

2

3

4

5

6

1-6 LINK TEST

NORM

TEST

RESET

7-12 LINK TEST

NORM

TEST

1-6 LINK TEST

NORM

TEST

This manual is related to the following products: