beautypg.com

Allied Telesis AT-MCF12VF, SM User Manual

Page 12

background image

Overview

4

Each twisted pair port has one LED labelled T-LNK that indicates whether or
not a link has been established between the port and the node connected to
the port. Each fiber optic port has two LEDs, one labelled F-LNK that lights
when a link has been established with the node connected to the port and
another LED labelled Active that lights when the port is receiving traffic.
Table 3 lists the functions of the port LEDs.

MAIN

Green

Flashing Green

The main power supply is functioning normally.

The main power supply is failing or has failed.

BCKP

Green

Flashing Green

The optional redundant power supply, if installed, is
functioning normally.

The optional redundant power supply, if installed, is failing
or has failed.

NORM

Green

The unit is not performing a link test.

TEST

Amber

The unit is performing a link test on the fiber optic ports
associated with the Link Test switch.

Table 3 Port LEDs

LED

Color

Indicates

T-LNK

Green

A link exists between the twisted pair port and the node to
which the port is connected.

F-LNK

Green

A link exists between the fiber optic port and the node to
which it is connected.

ACTIVE

Flashing
Amber

The fiber optic port is receiving data.

Table 2 Power Supply and Link Test Switch LEDs

LED

Color

Indicates

This manual is related to the following products: